Sertec

Sertec CMCE Installation Kit — 4 Grounding Plates for Dual CMCE

Price on application
SERTEC KIT#2
A four ground-plate grounding and bonding kit for dual Sertec CMCE installations, with four Glomex RA203 plates, an EGIS 5-stud bus bar, lugs, a ferrule and dielectric grease.
Price on application

This product is supplied to order and priced for each enquiry. Send us an enquiry quoting SKU SERTEC KIT#2 and we'll come back to you with a quote.

Enquire about this product

or call us on 023 8045 5129


Description

This is a complete grounding and bonding package designed for use with the Sertec CMCE lightning prevention system when four ground plates are required as part of a dual CMCE device installation. It is suitable for new builds and retrofit installations.

Kit contents:
• 4 × Glomex RA203 grounding plates
• 1 × EGIS 5-stud bus bar with protective cover
• 1 × 25 mm² (4 AWG) × 32 mm copper bootlace ferrule for the primary conductor
• 5 × 25 mm² (4 AWG) M10 copper cable lugs for primary and secondary conductors
• 4 × 25 mm² (4 AWG) M8 copper cable lugs for secondary conductor to ground plate connections
• 3 × 10 g tubes of dielectric grease for terminal stud protection

To achieve the intended performance of the Sertec CMCE lightning prevention system, installation should be carried out in accordance with the latest Sertec installation guidelines. Ground plates should be mounted below the waterline in a location that maintains continuous contact with seawater, one on either side of the keel line, ideally positioned fore and aft of each other. All grounding conductors should be as straight as practicable, avoiding sharp bends wherever possible. 25 mm² (4 AWG) copper conductor should be used between all system components. A second 6 mm² tinned cable may be used to connect chainplates and forestay where a carbon rig is fitted. Mechanical connections must be clean, secure and protected against corrosion, and dielectric grease should be applied to all exposed studs and terminals during assembly. The grounding network should be bonded to the vessel's designated lightning protection grounding arrangement, and installation should be verified and inspected by a suitably qualified marine electrician or installer for commissioning. The copper conductors themselves are specified for the installation; they are not listed among the kit contents.

PRODUCT DETAILS

  • Four ground-plate kit for dual Sertec CMCE device installation
  • 4 × Glomex RA203 grounding plates
  • EGIS 5-stud bus bar with protective cover
  • 25 mm² (4 AWG) copper lugs and ferrule, plus dielectric grease
  • Suitable for new builds and retrofit installations
  • 4 × Glomex RA203 grounding plates
  • 1 × EGIS 5-stud bus bar with protective cover
  • 1 × 25 mm² (4 AWG) × 32 mm copper bootlace ferrule
  • 5 × 25 mm² (4 AWG) M10 copper cable lugs
  • 4 × 25 mm² (4 AWG) M8 copper cable lugs
  • 3 × 10 g tubes of dielectric grease

No exploded diagram available for this product.

No compatible transducers listed for this product.

No spares or accessories listed for this product.

No compatible products found.

Kit contents

Grounding plates4 × Glomex RA203 grounding plates
Bus bar1 × EGIS 5-stud bus bar with protective cover
Ferrule1 × 25 mm² (4 AWG) × 32 mm copper bootlace ferrule for the primary conductor
M10 cable lugs5 × 25 mm² (4 AWG) M10 copper cable lugs for primary and secondary conductors
M8 cable lugs4 × 25 mm² (4 AWG) M8 copper cable lugs for secondary conductor to ground plate connections
Dielectric grease3 × 10 g tubes of dielectric grease for terminal stud protection

Installation

Intended useFor dual CMCE device installation when four ground plates are required
Ground plate positionBelow the waterline, in continuous contact with seawater; one on either side of the keel line, ideally fore and aft of each other
Primary conductor size25 mm² (4 AWG) copper conductor between all system components (conductors not listed in the kit contents)
Carbon rig bondingA second 6 mm² tinned cable may be used to connect chainplates and forestay where a carbon rig is fitted

No videos available for this product.

No downloads available for this product.

What is included?
4 × Glomex RA203 grounding plates; 1 × EGIS 5-stud bus bar with protective cover; 1 × 25 mm² (4 AWG) × 32 mm copper bootlace ferrule; 5 × 25 mm² (4 AWG) M10 copper cable lugs; 4 × 25 mm² (4 AWG) M8 copper cable lugs; and 3 × 10 g tubes of dielectric grease. The 25 mm² copper conductors used between system components are specified for the installation but are not listed among the kit contents.
When is this kit used instead of the two-plate kit?
This kit is for a dual CMCE device installation when four ground plates are required.
Where should the grounding plates be mounted?