Sertec CMCE Installation Kit — 2 Grounding Plates
This product is supplied to order and priced for each enquiry. Send us an enquiry quoting SKU SERTEC KIT#1 and we'll come back to you with a quote.
Enquire about this productor call us on 023 8045 5129
Description
This is a complete grounding and bonding package designed for use with the Sertec lightning prevention system. It brings together the essential components required for a dual ground plate installation. It is suitable for new builds and retrofit installations.
Kit contents:
• 2 × Glomex RA203 grounding plates
• 1 × EGIS 3-stud bus bar with protective cover
• 1 × 25 mm² (4 AWG) × 32 mm copper bootlace ferrule for the primary conductor
• 3 × 25 mm² (4 AWG) M10 copper cable lugs for primary and secondary conductors
• 2 × 25 mm² (4 AWG) M8 copper cable lugs for secondary conductor to ground plate connections
• 3 × 10 g tubes of dielectric grease for terminal stud protection
To achieve the intended performance of the Sertec CMCE lightning prevention system, installation should be carried out in accordance with the latest Sertec installation guidelines. Ground plates should be mounted below the waterline in a location that maintains continuous contact with seawater, one on either side of the keel line, ideally positioned fore and aft of each other. All grounding conductors should be as straight as practicable, avoiding sharp bends wherever possible. 25 mm² (4 AWG) copper conductor should be used between all system components. A second 6 mm² tinned cable may be used to connect chainplates and forestay where a carbon rig is fitted. Mechanical connections must be clean, secure and protected against corrosion, and dielectric grease should be applied to all exposed studs and terminals during assembly. The grounding network should be bonded to the vessel's designated lightning protection grounding arrangement, and installation should be verified and inspected by a suitably qualified marine electrician or installer for commissioning. The copper conductors themselves are specified for the installation; they are not listed among the kit contents.
PRODUCT DETAILS
- Dual ground-plate kit for the Sertec CMCE lightning prevention system
- 2 × Glomex RA203 grounding plates
- EGIS 3-stud bus bar with protective cover
- 25 mm² (4 AWG) copper lugs and ferrule, plus dielectric grease
- Suitable for new builds and retrofit installations
- 2 × Glomex RA203 grounding plates
- 1 × EGIS 3-stud bus bar with protective cover
- 1 × 25 mm² (4 AWG) × 32 mm copper bootlace ferrule
- 3 × 25 mm² (4 AWG) M10 copper cable lugs
- 2 × 25 mm² (4 AWG) M8 copper cable lugs
- 3 × 10 g tubes of dielectric grease
No exploded diagram available for this product.
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Kit contents
| Grounding plates | 2 × Glomex RA203 grounding plates |
| Bus bar | 1 × EGIS 3-stud bus bar with protective cover |
| Ferrule | 1 × 25 mm² (4 AWG) × 32 mm copper bootlace ferrule for the primary conductor |
| M10 cable lugs | 3 × 25 mm² (4 AWG) M10 copper cable lugs for primary and secondary conductors |
| M8 cable lugs | 2 × 25 mm² (4 AWG) M8 copper cable lugs for secondary conductor to ground plate connections |
| Dielectric grease | 3 × 10 g tubes of dielectric grease for terminal stud protection |
Installation
| Ground plate position | Below the waterline, in continuous contact with seawater; one on either side of the keel line, ideally fore and aft of each other |
| Primary conductor size | 25 mm² (4 AWG) copper conductor between all system components (conductors not listed in the kit contents) |
| Carbon rig bonding | A second 6 mm² tinned cable may be used to connect chainplates and forestay where a carbon rig is fitted |