The Simarine SCQ25T is a quadro shunt module for the PICO monitoring system. It has 4 independent measuring channels, each rated at 25 A continuous and 35 A peak for under 1 minute, so instead of only seeing the total battery current you can see exactly what a fridge, heater, inverter, water pump or solar charger is drawing or supplying. Readings are taken every 100 ms with 0.01 A resolution and ±1% accuracy.
On top of the four current channels, the SCQ25T adds 3 voltage inputs (0 to 75 V) and 4 resistance inputs (0 to 65 kΩ) for tanks and batteries, so one module can cover several consumers as well as tank levels and extra battery voltages. A built-in alarm relay rated 1 A at 12 V can be triggered by programmed conditions. Up to 5 quadro modules can be used for as many as 20 measured channels.
The module runs from 6 to 35 V DC with a consumption of around 2.5 mA, measures 183 x 91 x 34 mm and connects to the PICO display over the SiCOM data bus. Simarine makes the SCQ25T in Slovenia and covers it with a 3-year warranty.
PRODUCT DETAILS
- 4 independent current channels, 25 A continuous each
- 35 A peak per channel under 1 min
- 0.01 A resolution, ±1% accuracy, 100 ms sampling
- 3 voltage inputs (0 to 75 V) and 4 resistance inputs (0 to 65 kΩ)
- See consumption of individual appliances and charge sources
- Negative or positive side installation
- Alarm relay output, 1 A at 12 V
- SiCOM connection to PICO
- 6 to 35 V DC, 2.5 mA
- 3-year warranty, made in Slovenia
- SCQ25T quadro shunt module
- SiCOM data cable
No exploded diagram available for this product.
No compatible transducers listed for this product.
No spares or accessories listed for this product.
No compatible products found.
Measurement
| Channels | 4 independent current channels |
| Channel current | 25 A continuous, 35 A peak under 1 min |
| Range | 0.01 to 25 A per channel |
| Accuracy | ±1% |
| Resolution | 0.01 A |
| Sampling | 100 ms |
| Voltage drop | 30 mV |
Inputs
| Voltage inputs | 3 x 0 to 75 V |
| Resistance inputs | 4 x 0 to 65 kΩ |
Electrical
| Supply voltage | 6 to 35 V DC |
| Consumption | 2.5 mA |
| Maximum circuit voltage | 35 V DC |
| Alarm relay | 1 x output, 1 A at 12 V |
| Wiring | Negative or positive side |
Connectivity
| Data bus | SiCOM |
| Compatible displays | Simarine PICO |
Physical
| Dimensions | 183 x 91 x 34 mm |
Environmental
| Operating temperature | -20 to 70 °C |
General
| Part number | S004 |
| Warranty | 3 years |
| Country of origin | Slovenia |