Victron
Victron MultiPlus-II 12/3000/120-32 Inverter/Charger
Pickup available at Mercury Yacht Harbour
Usually ready in 2-4 days
Description
PRODUCT DETAILS
- Combined 12 V inverter, 120 A charger and 32 A transfer switch in one unit
- 3000 VA continuous output, 2400 W at 25°C and 5500 W peak power
- PowerControl and PowerAssist prevent overload of shore or generator supplies
- Uninterrupted changeover to inverter in under 20 milliseconds
- Two AC outputs, with the second output live only when AC input is present
- Parallel and three-phase capable for higher power installations
- ESS ready with built-in anti-islanding for grid-connected systems
- GX and VRM ready for local and remote monitoring and control
No exploded diagram available for this product.
No compatible transducers listed for this product.

Victron Temperature Sensor (MultiPlus/Quattro)

Victron Current Transformer 100A:50mA for MultiPlus-II (20m)

Victron MK3 to USB Interface

Victron Current Transformer 100A:50mA for MultiPlus-II (5m)

Victron Current Transformer 100A:50mA for MultiPlus-II (1m)

Victron MK3 to USB-C Interface

Victron VE.Bus Smart Dongle

Victron Lithium Battery Smart 12.8V/160Ah

Victron GX Touch 70 Display

Victron Cerbo GX MK2

Victron SmartShunt IP65 500A Battery Monitor

Victron Lithium Battery Smart 12.8V/180Ah

Victron Lithium Battery Smart 12.8V/50Ah

Victron SmartShunt IP65 1000A Battery Monitor

Victron Lynx Smart BMS 500 (M8)

Victron GX Touch 50 Display

Victron Lynx Smart BMS 1000 (M10)

Victron Lithium Battery Smart 12.8V/200Ah

Victron Lithium Battery Smart 12.8V/100Ah

Victron Ekrano GX
Key specifications
| System voltage | 12 V |
| Continuous output power | 3000 VA |
| Continuous output power at 25°C | 2400 W |
| Peak power | 5500 W |
| Maximum charge current | 120 A |
| Transfer switch | 32 A |
Inverter
| DC input voltage range | 9.5 to 17 V |
| Output voltage / frequency | 230 VAC +/-2%, 50 Hz +/-0.1% |
| Cont. output power at 25°C (VA) | 3000 VA |
| Cont. output power at 25°C (W) | 2400 W |
| Cont. output power at 40°C (W) | 2200 W |
| Cont. output power at 65°C (W) | 1700 W |
| Peak power | 5500 W |
| Maximum efficiency | 93 % |
| Zero load power | 13 W |
| Zero load power in AES mode | 9 W |
Charger
| Charge voltage 'absorption' | 14.4 V |
| Charge voltage 'float' | 13.8 V |
| Storage mode | 13.2 V |
| Maximum charge current | 120 A |
| Battery temperature sensor | Yes |
Connectivity & control
| VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration |
| General purpose comms port | Yes, 2x |
| Programmable relay | Yes (general alarm, DC under voltage or genset start/stop) |
| Remote on/off | Yes |
| External AC current sensor (optional) | 50 A or 100 A |
Protection
| Protection | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on inverter output, input voltage ripple too high |
Environmental
| Operating temperature range | -40 to +65 °C (fan assisted cooling) |
| Humidity (non-condensing) | Max. 95 % |
| Maximum altitude | 2000 m |
Physical
| Material & colour | Steel, blue RAL 5012 |
| Protection category | IP22 |
| Battery connection | M8 bolts |
| 230 VAC connection | Screw terminals 13 mm² (6 AWG) |
| Weight | 19 kg |
| Dimensions (h x w x d) | 546 x 275 x 147 mm |
Conformance
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission / Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1/-6-2/-6-3 |